ModularSensors > Classes > Sensor > SDI12Sensors > InSituRDO
ModularSensors > Modules > In-Situ RDO PRO-X > InSituRDO


InSituRDO class

The Sensor sub-class for the In-Situ RDO PRO-X dissolved oxygen sensor.

Base classes

class SDI12Sensors
The main class for SDI-12 Sensors.

Constructors, destructors, conversion operators

InSituRDO(char SDI12address, int8_t powerPin, int8_t dataPin, uint8_t measurementsToAverage = 1)
Construct a new In-Situ RDO object.
InSituRDO(char* SDI12address, int8_t powerPin, int8_t dataPin, uint8_t measurementsToAverage = 1)
Construct a new In-Situ RDO object.
InSituRDO(int SDI12address, int8_t powerPin, int8_t dataPin, uint8_t measurementsToAverage = 1)
Construct a new In-Situ RDO object.
~InSituRDO()
Destroy the In-Situ RDO object.

Function documentation

InSituRDO(char SDI12address, int8_t powerPin, int8_t dataPin, uint8_t measurementsToAverage = 1)

Construct a new In-Situ RDO object.

Parameters
SDI12address The SDI-12 address of the RDO; can be a char, char*, or int.
powerPin

The pin on the mcu controlling power to the RDO PRO-X Use -1 if it is continuously powered.

  • The RDO PRO-X requires a 8-12V power supply, which can be turned off between measurements
dataPin The pin on the mcu connected to the data line of the SDI-12 circuit.
measurementsToAverage The number of measurements to take and average before giving a "final" result from the sensor; optional with a default value of 1.

The SDI-12 address of the sensor, the Arduino pin controlling power on/off, and the Arduino pin sending and receiving data are required for the sensor constructor. Optionally, you can include a number of distinct readings to average. The data pin must be a pin that supports pin-change interrupts.


InSituRDO(char* SDI12address, int8_t powerPin, int8_t dataPin, uint8_t measurementsToAverage = 1)

Construct a new In-Situ RDO object.

Parameters
SDI12address The SDI-12 address of the RDO; can be a char, char*, or int.
powerPin

The pin on the mcu controlling power to the RDO PRO-X Use -1 if it is continuously powered.

  • The RDO PRO-X requires a 8-12V power supply, which can be turned off between measurements
dataPin The pin on the mcu connected to the data line of the SDI-12 circuit.
measurementsToAverage The number of measurements to take and average before giving a "final" result from the sensor; optional with a default value of 1.

The SDI-12 address of the sensor, the Arduino pin controlling power on/off, and the Arduino pin sending and receiving data are required for the sensor constructor. Optionally, you can include a number of distinct readings to average. The data pin must be a pin that supports pin-change interrupts.


InSituRDO(int SDI12address, int8_t powerPin, int8_t dataPin, uint8_t measurementsToAverage = 1)

Construct a new In-Situ RDO object.

Parameters
SDI12address The SDI-12 address of the RDO; can be a char, char*, or int.
powerPin

The pin on the mcu controlling power to the RDO PRO-X Use -1 if it is continuously powered.

  • The RDO PRO-X requires a 8-12V power supply, which can be turned off between measurements
dataPin The pin on the mcu connected to the data line of the SDI-12 circuit.
measurementsToAverage The number of measurements to take and average before giving a "final" result from the sensor; optional with a default value of 1.

The SDI-12 address of the sensor, the Arduino pin controlling power on/off, and the Arduino pin sending and receiving data are required for the sensor constructor. Optionally, you can include a number of distinct readings to average. The data pin must be a pin that supports pin-change interrupts.